How to Collimate a Newtonian Telescope, Step by Step

EyepieceLab is reader-supported. If you buy through our links we may earn a commission at no extra cost to you. As an Amazon Associate we earn from qualifying purchases. Disclosure.
If your reflector's stars won't focus to clean points, the mirrors may be slightly out of line. This walkthrough follows Celestron's knowledge base article on collimating a Newtonian in daylight, then checks which scopes on this site need it, using Celestron's and Sky-Watcher's spec pages. Product details are from the listings.
Does your telescope need it?
Celestron: "The optical performance of most Newtonian reflecting telescopes can be optimized by re-collimating (aligning) the telescope's optics, as needed." That includes Dobsonians. Celestron says the Maksutov-Cassegrain design "never needs to be collimated." Refractors generally don't need user collimation.
Which scopes on this site need it, and what you're working with
Collimation depends on the design, and how forgiving a scope is depends on its mirror and focal ratio. Sky-Watcher's guide to optical aberrations says that lengthening the focal length "results in a higher focal ratio and the aberrations become less pronounced," so the slower the mirror the more room for error. The table lists every reflector and catadioptric on this site with the design, mirror type and focal ratio from the maker's spec page, whether the maker packs a collimation tool, and what Celestron's guidance says about adjusting it.
| Scope | Design and primary mirror (maker) | Focal ratio | Collimation tool in the box (maker) | Needs user collimation? |
|---|---|---|---|---|
| Celestron AstroMaster 130EQ | Newtonian, spherical | f/5 | Not listed | Yes, both mirrors (Celestron) |
| Celestron StarSense Explorer DX 130AZ | Newtonian, parabolic | f/5 | Not listed | Yes |
| Celestron StarSense Explorer LT 114AZ | Newtonian, spherical | f/9 | Not listed | Yes; the longest Newtonian ratio here, so the most forgiving by Sky-Watcher's rule |
| Celestron PowerSeeker 127EQ | Newtonian, spherical | f/7.87 | Not listed | Yes |
| Sky-Watcher Heritage 130P | Newtonian, parabolic | f/5 | Not listed | Yes; collapsible tube, so check after extending |
| Sky-Watcher Classic 150P | Newtonian, parabolic | f/8 | Not listed | Yes, but the slowest Dob here |
| Sky-Watcher Classic 200P / Flextube 200P | Newtonian, parabolic | f/5.9 | Not listed | Yes; Sky-Watcher says the Flextube struts keep collimation when collapsed |
| Celestron StarSense Explorer 8 in. Dobsonian | Newtonian, parabolic | f/5.9 | Collimation cap | Yes |
| Celestron StarSense Explorer 10 in. Dobsonian | Newtonian, parabolic | f/4.7 | Collimation cap | Yes; the fastest mirror on this site, so the least margin |
| Celestron NexStar 6SE / 8SE | Schmidt-Cassegrain | f/10 | Not listed | Per the maker; Celestron's useful-magnification figures assume collimated Cassegrains |
| Sky-Watcher Skymax 102 / 127, Celestron NexStar 4SE, 90SLT, 127SLT | Maksutov-Cassegrain | f/12 to f/14 (maker) | Not applicable | No: Celestron's glossary says the design "never needs to be collimated" |
| Any refractor on this site | Lens | f/5 to f/13 | Not applicable | No user collimation; Celestron's guidance covers Newtonians and Cassegrains |
Three practical points fall out of the table. Celestron says to re-collimate "as needed," and by Sky-Watcher's focal-ratio rule the f/4.7 and f/5 rows will need it more often than the f/8 and f/9 rows, so owners of fast Newtonians should make the cap check part of setup. A laser or Cheshire is worth buying only for the Newtonian rows. A Maksutov owner has nothing to adjust, and a Schmidt-Cassegrain owner should follow Celestron's instructions for that design rather than the Newtonian method on this page.
What you're adjusting
- Primary mirror: the big one at the bottom of the tube, adjusted by "three screws, placed 120 degrees apart" (Celestron).
- Secondary mirror: the small elliptical mirror under the focuser, which "also has three adjustment screws."
- Locking screws: "Always loosen the locking screws first before turning any of the collimation screws," and retighten them when done.
Step by step (Celestron's method)
- Get a collimating tool (Celestron mentions a collimating cap; a Cheshire eyepiece or laser also works) and rack the focuser all the way in.
- Center the primary in the secondary. Look through the tool. If the primary mirror isn't centered in the secondary, "adjust the secondary mirror screws by alternately tightening and loosening them until the periphery of the primary mirror is centered in your view." Celestron says not to touch the secondary's center screw.
- Adjust the primary. "Adjust the primary mirror screws to re-center the reflection of the small secondary mirror, so it's silhouetted against the view of the primary."
- Check and repeat. "As you look into the focuser, silhouettes of the mirrors should look concentric. Repeat steps one and two until you have achieved this."
- Lock it. Tighten the locking screws.
Tools
Celestron Cheshire Collimation Eyepiece
- 1.25 in. Cheshire collimating eyepiece
- For collimating Newtonians
Astromania 1.25 in. Cheshire Collimating Eyepiece (Long)
- Fits 1.25 in. focusers; cap the scope and drop it in
- Long version, made for Newtonian reflectors
- Aluminum body with crosshair and 45-degree reflective plate
SVBONY Laser Collimator
- For 1.25 in. and 2 in. Newtonian focusers
- 7 brightness levels
- Metal body; 2 in. adapter included
Why it matters
Celestron's published highest useful magnifications assume "well collimated optics (for Newtonians and Cassegrains)." A badly aligned scope won't reach them. See magnification explained.
FAQ
What is collimation?
Celestron defines it as the proper alignment of the optical elements in your telescope (its lenses and mirrors), and says poor collimation causes aberrations and distorted images.
Which telescopes need collimating?
Mainly Newtonian reflectors, including Dobsonians. Celestron's magnification limits assume well-collimated optics for Newtonians and Cassegrains. Celestron says the Maksutov-Cassegrain design never needs it.
Laser or Cheshire collimator?
Both work. A Cheshire eyepiece needs no batteries; a laser gives a bright dot to align. Celestron's own guide starts with a simple collimating cap or tool.
Does a fast telescope need collimating more carefully?
Sky-Watcher's guide to optical aberrations says a higher focal ratio makes aberrations less pronounced, so an f/4.7 or f/5 Newtonian has less margin for error than an f/8. Celestron packs a collimation cap with its f/5.9 and f/4.7 StarSense Dobsonians; its f/5 AstroMaster and StarSense DX 130 kits do not list one.
Sources
- Celestron: Collimating a Newtonian in daylight
- Celestron: Astronomy glossary
- Celestron: Which eyepieces to use
- Celestron: AstroMaster 130EQ specs
- Celestron: StarSense Explorer DX 130AZ specs
- Celestron: StarSense Explorer LT 114AZ specs
- Celestron: StarSense Explorer 8 in. Dobsonian specs
- Celestron: StarSense Explorer 10 in. Dobsonian specs
- Sky-Watcher USA: Classic Dobsonian product sheet (PDF)
- Sky-Watcher USA: Flextube/Heritage product sheet (PDF)
- Sky-Watcher: Correcting optical aberrations